Criticare 8100 Poet Plus CO2 Veterinary Monitor

SKU: C8PP0813
Units in Stock: 1
Criticare 8100 Poet Plus Vital Signs CO2 Veterinary ECG Monitor is preowned and in good condition.
Condition: Good
Type: PreOwned
Price: $1,295.00
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
Criticare 8100 Poet Plus CO2 Veterinary Monitor
(Click to see larger image and other views)
Product Details

Criticare 8100 Poet Plus Vital Signs CO2 Veterinary Monitor - Preowned in Good Condition

 

 

VENDOR DESCRIPTION

 

Poet Plus® 8100 is the perfect choice for busy departments demanding maximum flexibility, unsurpassed ease of use, and accurate, reliable performance. Respond to every monitoring need, from standard vital signs to conscious sedation. Monitor adults, pediatrics, and neonates in virtually every department, at bedside or in transit. The Poet Plus 8100 mounts quickly and easily to walls, roll stands, and bedrails.

 

With the compact, lightweight Poet Plus 8100, you focus on your patients, not your monitor. The innovative user interface with simple, one-level menus and dedicated function keys ensures super-fast set-up. The big, bright display with large numerics is easily seen, even from across the room.

 

 

FEATURES

 

Easy-to-read 10.4" active TFT color display

View up to 6 waveforms simultaneously.

Easy to learn, easy to use menus, dedicated function keys, and simplified controls

Smart battery management with rechargeable "hot-swappable" sealed lead acid batteries

Lightweight design and versatile mounting options

Adapts readily to department and transport requirements

 

 

SPECIFICATIONS

 

System Outputs

Communication Ports: RS-232 compatible; DB9, analog mini-din 
Nurse Call: contact switch, stereo jack 3.5 mm, length 14 mm standard

Defib / Sync: BNC connector

Video Port: high density D-sub 15-pin

 

Recorder

Type: Thermal Line Printer

Paper speed: 12.5, 25, 50mm/sec

 

Mechanical

Weight: Base unit without batteries: 12 lbs, 5.45kg

Size: Base unit: 13.25 "(H) x 12.5" (W) x 8.75 "(D)

 

Power Requirements

Voltage: 100, 120, 220, 240 VAC, 50/60 Hz

Consumption: 35 W, typical

Batteries: 2, Sealed Lead Acid, life: 2 hr, typical recharge time: 4.5 hours

 

ECG

Connectors: 3- or 5-lead

Leads: User-selectable; I, II, III, aVR, aVL, aVF, V (5-lead); I, II, or III (3-lead)

Gain Selection: 1/2mV, 2mV, 4mV

Frequency Response:
- Diagnostic: 0.05 to 100 Hz (-3db);
- Monitor: 0.5 to 40 Hz (-3db)

Sweep Speed: 12.5, 25, 50mm/sec

Electrosurgery Protection: Yes

Defibrillator Protection: Yes

Pacer Detection/Rejection: Yes

 

Non-Invasive Blood Pressure

Technique: Oscillometric measure upon inflation

Automatic Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr

Measurement Range: Adult: 30 to 300mmHg; Neonate: 0 to 150 mmHg

Resolution: 1mmHg

Transducer Accuracy: ±2mmHg or ±2% of reading, which ever is greater, over full range

STAT mode: 5 min of consecutive readings

 

Pulse Oximetry

Range: 1% to 99%

Resolution: 1%

Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified

Method: Dual wavelength LED

 

Heart (Pulse) Rate

Source: ECG (primary); IBP, Pleth; NIBP

Range: 20 to 300bpm

Accuracy: ±1bpm or ±1% (ECG, IBP, SPO2 only)

 

Temperature

Channels: 2

Range, Accuracy:
68° to 94.8° F: ±0.5%;
95° to 107.4° F (35° to 41.9° C): ±0.2%;
107.6° to 113° F (42° to 45° C): ±0.5%

Probe: YSI-400 and YSI-700 series

 

Respiration

Rate: 6 to 150 breaths/min

Resolution: 1 breath/min

Accuracy: ±1% or ±1 breath/min, whichever is greater

Source: User selectable: Smart, CO2, ECG-TTI

 

CO2

Units: mmHg; Torr; %; kPa

Waveform Scale: 0 to 3.13%, 0 to 6.25%, 0 to 12.5% and 0 to 25%

Method: Non-dispersive infrared; auto calibrating

N2O Compensation: Manual; On/Off, user selectable

Range: 0 to 99mmHg; 0 to 99 Torr; 0 to 12.5%; 0 to 12.5 kPa

Resolution: 1mmHg; 1 Torr; 0.1%; 0.1 kPa

Sample Rate: Sidestream, selectable: 150ml/min or 50ml/min

Accuracy:
+2mmHg, ±0.3 volume %, ±0.3 kPa, or ±2 Torr at 150ml/min and respiratory rate of ±35 breaths/min

Rise Time: 350ms at 150ml/min (10 to 90%)

   

 

RESOURCES

 

Criticare 8100 Poet Plus Vital Signs Brochure

 

 

CONTENTS

 

Qty - 1 Criticare 8100 Poet Plus Vital Signs Monitor 81C001P (CO2 with Printer)

Qty - 1 Criticare SpO2 Extension Cable and Sensor with Ear Clip Attachment

Qty - 1 AMC 3-Lead ECG Cable CB-71320R (NEW)

Qty - 1 AMC 3-lead DIN to Snap Leadset LW-2090024/3A (NEW)

Qty - 1 Small Blood Pressure Cuff and Hose
Qty - 1 YSI Temperature Probe C400-10 Reusable Cable with Sensor

 

Only items specified in the contents section are available with product.

 

 

CONDITION

 

Cosmetic - Good

Working - Good

 

Please contact us for any more information

 