Titmus V2, V4 Series Vision Slides

SKU: TV4SLIDES
Brand: Titmus
Units in Stock: 3
Titmus V2, V4 Series Vision Slides - New
Condition: New
Type: New
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
Titmus V2, V4 Series Vision Slides
(Click to see larger image and other views)
Product Details

Titmus V2, V4 Series Vision Slides - New

Vision testing slides for Titmus Model V4, and V2 are available individually.

Landolt Ring Slide for Right Eye (SAR-1) is used to test visual acuity in the right eye. Same as Both Eyes, except Landolt Ring symbols are omitted from left eye area. Permits measuring the habitual functioning of the right eye while both eyes look at the slide.

Landolt Ring Slide for Left Eye (SAL-1) is used to test visual acuity in the left eye. Same as Both Eyes, except Landolt Ring symbols are omitted from right eye area. Permits measuring the habitual functioning of the Left Eye while both eyes look at the slides

Allen Picture Slide (SA-APS1) Visual Acuity Test measures binocularity and acuity. Line 1 tests performance of both eyes together and Lines 2, 3 and 4 test acuity for right and left eyes calibrated at 20/30, 20/40 and 20/50

E-Symbols Slide for Both Eyes SAS-2 meaasures Acuity in right and left eyes with Conventional Tumbling "E" symbol. Patient states which way the "E" points in each square.

Heterophoria Slide SPS-3 measures Heterophorias. Muscle imbalance - vertical and lateral - is tested at predetermind pass/fail levels. This test is administered first at far, then at near.

Acuity Slide SMPS-30-2 Right and Left Eye. The "E” points in a different direction for each eye. Test No. 3 in Pediatric Model of Titmus Vision Testing Systems.

Acuity Slide SMPS-30-3 Right and Left Eye. The "E” points in a different direction for each eye. Test No. 4 in Pediatric Model of Titmus Vision Testing Systems.

Michigan Preschool Binocularity Test SMPS-B2 Binocularity for both eyes. Tests performance of both eyes together. Test #1 for Pediatric Model of Titmus Vision screeners 

Color Perception Test Slide (CDF-1) is used to test color perception, and consists of six accurately and authentically reproduced Ishihara Pseudo-Isochromatic plates. Detects color deficiency, but does not classify.

Landolt Ring Slide for Both Eyes (SAB-1) is used to test visual acuity in both eyes. This psychologically sound pattern of Landolt Rings provides a precise measure of acuity with literates or illiterates. Easy to administer. The test symbol to be identified is the unbroken ring.

 

SPECIFICATIONS:

Each slide is 3 15/16" x 1 7/16" 

CONTENTS:

Each slide is Priced at $75.00 and can be selected on the SLIDE CHOICE DROP DOWN OPTION